Fusion-Tested. Quality Guaranteed.
Combining advanced technology and proprietary data with expert engineering and quality teams to maintain consistent testing standards across all facilities.
Full Specifications
- ESD Protection
- No
- Operating Supply Voltage
- 3.3V
- Lifecycle Status
- Production
- Mount
- Surface Mount
- Case/Package
- SOIC
- Number of Pins
- 16
- Packaging
- Tape & Reel
- Package Quantity
- 2,500
- Min Supply Voltage
- 3.1V
- Max Supply Voltage
- 3.4V
- Min Operating Temperature
- -25°C
- Max Operating Temperature
- 85°C
- RoHS
- Compliant
- Ambient Temperature Range High
- 85°C
- Height
- 1.75mm
- High Level Output Current
- 100µA
- Lead Free
- Lead Free
- Length
- 9.9mm
- Low Level Output Current
- 100µA
- Manufacturer Lifecycle Status
- Active
- Max Junction Temperature (Tj)
- 150°C
- Nominal Supply Current
- 650µA
- Number of Transceivers
- 1
- Polarity
- Inverting
- Radiation Hardening
- No
- Schedule B
- 8542390000
- Weight
- 155.100241mg
- Width
- 3.91mm
Key Features
- Single M-Bus Transceiver channel, Inverting Polarity
- 3.3V Operating supply, 3.1V to 3.4V Range
- 650µA Nominal Supply Current
- 100µA High-Level and Low-Level Output Drive Current
- 16-Pin SOIC package, 9.9mm X 3.91mm X 1.75mm
- -25°C to 85°C Operating range, RoHS Compliant and Lead Free
About this Product
The TSS721ADR is a Meter-Bus (M-Bus) interface transceiver from Texas Instruments in a 16-pin SOIC package. It operates from a 3.3V supply spanning 3.1V to 3.4V, drawing 650µA nominal supply current, and provides a single inverting transceiver channel with 100µA high- and low-level output drive. The TSS721ADR handles the physical-layer signalling between a metering device and a two-wire M-Bus, and Texas Instruments lists it as active production.
Common Uses
What is the Texas Instruments TSS721ADR M-Bus Interface Transceiver Used For?
The TSS721ADR sits at the slave end of a Meter-Bus network, the two-wire field bus used across Europe for remote reading of utility meters. It handles the bus-side signalling and power extraction so a low-power microcontroller inside a heat, water, gas or electricity meter can communicate with a central data collector over long cable runs. Typical products are submetering modules, heat cost allocators, building automation concentrators and district heating instrumentation. Buyers are metering and building-automation OEMs and the contract manufacturers building certified M-Bus endpoints. Note that this part is filed under USB Interface ICs in the catalogue, which does not match its M-Bus function.
Certifications & Memberships
Fusion’s in-house quality hubs and Prosemi testing facility are fully certified to meet critical industry standards for electronic component inspection and testing.
Fusion-Tested. Quality Guaranteed.
Combining advanced technology and proprietary data with expert engineering and quality teams to maintain consistent testing standards across all facilities.